High-Pressure FLR recovery and relaunch
- : [ PD50/1000+RTF500/900LF+HY-RF4/2+VAAP]
- : 2008
- Special high-performance plant, complete with :
- evacuator for chip recovery/elimination;
- 2 FLR filtration steps, 200 µm→25 µm;
- FLR relay to medium/high pressure U.M;
- thermal control unit.
Performance and key data
- Chip type: Aluminum
- Chip morphology: Short with small bundles
- Chip throughput Ṁ= 100 kg/h
- Coolant type: Oil-based emulsion 6-10%
- Total volumetric capacity V= 3,600 liters
- Machine tool carter washing: Q̇ = 400 L/min H = 4.0 bar G.F. = 200 µm
- External cooling: Q̇ = 40 L/min H = 6.0 bar G.F. = 25 µm
- Internal cooling: Q̇ = 30-40 L/min H = 15-70 bar G.F. = 25 µm
- Differential thermal control: ΔT = Tambient - Tfluid = ±2 °C
Component description
- Drag Flight Conveyor
- Rotary Pre-Filtration Unit Q̇ = 500 L/min G.F. = 200 µm
- Pre-Filtered Coolant Tank
- Filtration Unit Q̇ = 120 L/min G.F. = 25 µm
- Filtered Coolant Tank
- Multi-Step Pressure Control Unit H = 15-70 bar
- Oil Skimmer with Waste Oil Recovery Concentrator
- Refrigeration Unit with Submerged Coil P = 10,000 W
- Forced Recirculation Unit to the Machine Base for Thermoregulation
Documentation and manuals
Documentation in Italian and English compliant with the Machinery Directive 98/37/EC, including the Manufacturer's Declaration of Conformity, Annex II, Type B.
Request information
Contact us, our Sales Department ensures that every request is met.
Counseling
Technical information according to customer requirements
Sale
Technical and business consulting and proposal
Training
Courses in good plant operation
Assistance
Technical Service, Parts, Repair and Overhaul